Lasting accuracy for diaphragm seal systems for vacuum process

A diaphragm seal system in a vacuum process must master a significant challenge ? Pale must deliver a trusted measuring result, even though the pressure drops and the temperature rises concurrently. The example of a chemical company producing phthalic anhydride (PA) shows that it is by no means self-evident that requirement can be met on a frequent basis.
PA is primarily used as a plasticiser for plastics. However, additionally it is found in the production of synthetic resins and dyes. The plant operator obtains this compound via the catalytic oxidation of o-xylene in the gas phase, accompanied by vacuum pressure distillation process.
Critical phase for pressure measurement
In this process, the critical phase for pressure measurement occurs in the distillation column. There, the procedure temperature can rise to more than 230 �C while the pressure drops to 100 mbar abs. With this type of contrary action, the conventional installed measurement technology reaches its performance limit relatively quickly, which the aforementioned manufacturer was forced to learn ? all instrumentation showed a measurement deviation beyond your defined tolerance after only a fortnight.
Diaphragm seal system adapted in every elements to the vacuum process
The diaphragm seal system is tailored exactly to the conditions of the vacuum process and tested under application conditions.
Consequently, the company approached WIKA with the obtain a measuring solution that would also fulfil its task with the mandatory accuracy in the long run under the conditions described. WIKA then drew on its in-depth expertise to design a diaphragm seal system for the vacuum process, consisting of a process transmitter (model IPT-20), a flange-type diaphragm seal with flush diaphragm (model 990.27) and a capillary.
All elements of this measuring system were selected specifically for the application. Silicone oil KN32 was therefore selected as the fill fluid for pressure transmission. The cleaning and conditioning of the diaphragm seal, the capillary, the connection pieces as well as the automated filling process were also matched to each other exactly. With sensitive limit ranges, even one drop of liquid an excessive amount of or inadequate can destabilise the volume balance of the diaphragm seal system and thus impair its function. Consequently, correct measurement would no longer be guaranteed.
Test under application conditions
After cleaning, all elements of the diaphragm seal system were first fully welded right into a single unit as usual, followed by the filling and adjustment of the machine. Before delivery, however, there is another crucial step ? in its laboratory, WIKA simulated a vacuum process for the diaphragm seal system relative to the customer?s conditions and subjected it to a thermal ageing process. This test confirmed the procedure suitability of the measuring system.
Note
Further information on the WIKA diaphragm seal systems can be found on the WIKA website. In case you have any questions, your contact will gladly assist you to.
Also read our posts
Diaphragm seals for stable flow measurement in deep seas
Just how do diaphragm seals work?
Watch the next video for more information about the functionality, application areas and benefits of diaphragm seals:

Leave a Comment